DK37 M8
The DK37 M8 is a variable area (VA) flowmeter with electrical signal output and bargraph indication or mechanical indicator with two optional limit switches. The versatile all-metal measuring device is suitable for flow measurement of gases and liquids. Due to its sturdy design, the VA meter can be used at temperatures up to +200°C / +392°F or pressures up to 220 barg / 3190 psig. It is fitted with a needle valve as standard to accurately set the flow value.
The DK37 M8 comes with vertical or horizontal process connections for NPT or G thread, flange adapters and many other connection options. To provide constant flow rates in case of variable inlet or outlet pressures, the VA meter is also available with flow regulators. It has approvals for hazardous areas and is suitable for use in Safety Instrumented Systems (SIS).
Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.
- Simple, low-cost installation: Able to measure and display without auxiliary power supply
- Purgemeter with 2 optional limit switches or 4…20mA/HART® for flow monitoring
- Various stainless steel and alloy sensor materials
- Optional surface passivation with SilcoNert®2000 for trace-level analysis
- PPS housing as standard, stainless steel housing as option
- Ingress protection IP66/67
- Full scale value for liquids: 1.6…250 l/h / 0.4…67 GPH
- Full scale value for gases: 16…8,000 l/h / 0.6…300 SCFH
- Turndown ratio 10:1
- Maximum measuring error: ±2.5% (acc. to VDI/VDE 3513-2) or ±2% of full scale
- Suitable for use in Safety Instrumented Systems with SIL 2, in redundant design (1oo2) also in SIL 3 applications (type A device)
- Approved for hazardous areas
Have a project in mind that you think we’d be a great fit for it? We’d love to know what you’re thinking
Get in Touch
Frequently Asked Questions
No accordion items found.